Inverting Remote On-Off Cable
Cable used to connect (disconnected) Phoenix 12/180, 24/180, 12/350, or 24/350 inverters to VE.Bus BMS or BlueSolar MPPT chargers equipped with a ballast cell.
- On request
Product details
- Brand
- Victron Energy
- Reference
- ASS030550120
- EAN13
- 8719076036470
- MPN
- ASS030550120
Data Sheet
| Category |
|---|
| Accessories |
Description
Description
Inverting remote on-off cable
The inverting remote on-off cable enables remote control of Victron Energy devices - Phoenix inverters, chargers, and controllers. It facilitates switching PV systems on and off, ensuring reliable and safe operation.
This cable should be used to connect (disconnected) Phoenix 12/180, 24/180, 12/350, or 24/350 inverters to VE.Bus BMS or BlueSolar MPPT chargers equipped with a load cell:
- VE.Bus BMS: The inverter will switch off when the batteries are discharged
- BlueSolar MPPT charger: it is not possible to connect the inverter directly to the load cell output of the BlueSolar MPPT charger; the inverter must be connected to the battery. Then use this cable to turn the inverter on and off with the load cell output.
Key Features
Discover the advantages that make a difference
Remote Control
The cable enables immediate on/off switching of the system from a distance, significantly improving the comfort of daily device operation.
Versatile Integration
The product is designed with full compatibility in mind, making it easy to build consistent and flexible installations.
Power consumption optimization
Quick access to power control allows limiting unnecessary energy consumption and effectively increases the protection level of the entire system.
Example no. 1
Inverting remote on-off cable (1) used to interface between the load output of the MPPT 75/15 or MPPT 100/15 and the Phoenix inverters model 12/180, 24/180, 12/350, 24/350.
(The Victron inverters model Phoenix 12/800, 24/800, 12/1200 and 24/1200 require active pull up to switch on and can be controlled by connecting the right side connection of the inverter remote control directly to the load output of the solar charger).
Example no. 2
Inverting remote on-off cable (1) used to interface between the load disconnect output of the VE.BUS BMS and the Phoenix inverters model 12/180, 24/180, 12/350, 24/350, 48/350.
Similarly, the Inverting remote on-off cable can be used to interface between the VE.BUS BMS and Phoenix Inverters rated at 3kVA and more.
Specifications
Inverting remote on-off cable |
|
|
Maximum input voltage |
70 V |
|
Maximum output voltage |
70 V |
Minimum input voltage needed for pull down |
approximately 6 V |
Maximum pull down current |
approximately 30 mA (short circuit proof) |