BlueSolar charge controller | MPPT 100/30 | ||
Battery Voltage | 12/24V with automatic system voltage detection | ||
Rated charge current | 30A | ||
Maximum PV power, 12V 1a,b) | 440 W (MPPT range 15 V to 80 V) | ||
Maximum PV power, 24V 1a,b) | 880 W (MPPT range 30 V to 80 V) | ||
Maximum PV open circuit voltage | 100 V | ||
Peak efficiency | 98 % | ||
Self-consumption | 10mA | ||
Charge voltage 'absorption' | Default setting: 14,4 V / 28,8 V (adjustable) | ||
Charge voltage 'float' | Default setting: 13,8 V / 27,6 V (adjustable) | ||
Charge algorithm | multi-stage adaptive | ||
Temperature compensation | -16 mV / °C resp. -32 mV / °C | ||
Protection | Battery reverse polarity (fuse, not user accessible) Output short circuit Over temperature |
||
Operating temperature | -30 to +60°C (full rated output up to 40°C) | ||
Humidity (non condensing) | Max 95 % | ||
Data communication port | VE.Direct See the data communication white paper on our website |
||
ENCLOSURE | |||
Colour | Blue (RAL 5012) | ||
Power terminals | 13 mm² / AWG6 | ||
Protection class | IP43 (electronic components), IP22 (connection area) | ||
Weight | 1,25 kg | ||
Dimensions (h x w x d) | 130 x 186 x 70 mm | ||
STANDARDS | |||
Safety | EN/IEC 62109 | ||
1a) If more PV power is connected, the controller will limit input power to 440W resp. 880 W 1b) PV voltage must exceed Vbat + 5V for the controller to start. Thereafter minimum PV voltage is Vbat + 1V |
Instalacje fotowoltaiczne
Magazynowanie Energii
Projekty
Wykonawstwo